Converter BOARD 5V / 24V Type 3911

Type 3911

Converter BOARD 5V / 24V Type 3911

The Converter BOARD 5V / 24V Type 3911 is a universal level and interface board for 5 V and 24 V signals. Optocouplers, relays, a built-in power supply and short-circuit proof outputs make the board suitable for automation and mechatronics tasks.

  • Level conversion from 5 V to 24 V and from 24 V to 5 V
  • Galvanic isolation of the 5 V and 24 V connections by optocouplers
  • 8 digital 5 V inputs to 8 digital 24 V outputs
  • 8 digital 24 V inputs to 8 digital 5 V outputs
  • Built-in power supply
  • Freely wired relays
Datasheet (PDF)

Level Conversion and Isolation

The Converter BOARD is used to convert 5 V and 24 V signals in both directions. The two voltage domains are galvanically isolated by optocouplers.

The board can be operated with standard leads as well as safety leads. An adapter for connecting mechatronic systems is integrated.

Application Areas

The board is intended for mechatronic systems, automation technology, control applications, electropneumatic systems, industrial controls, small controls, PLCs and digital control systems.

The outputs are short-circuit proof and indicated by LEDs, making the switching state and signal flow easy to observe.

  • All outputs short-circuit proof
  • Output states indicated by LEDs
Mains supply
220 V AC ... 240 V AC / 115 V AC (110 V AC), approx. 40 VA, 50 ... 60 Hz
Inputs / outputs
8 inputs 24 V DC, 1 output 24 V DC / 750 mA, 7 outputs 24 V DC / 75 mA, 8 inputs 5 V, 8 outputs 5 V
Relays
coil voltage 24 V DC; 1 changeover contact 230 V / 3 A
Mechatronics adapter
9-pin Sub-D socket for connecting mechatronic systems
Front panel
5 mm laminated press material
Rear side
plastic cover
Dimensions
266 x 297 x 220 mm
Weight
approx. 2.4 kg

Taken from the tables of contents of the hps experiment manuals (titles, numbers and pages). All manuals are German; titles are shown in the original language. All manuals and experiments

V 0174 Grundlagen der Automatisierungstechnik mit SIMATIC STEP 7 Manual · 240 pages 1 experiment

Additional device in this manual View table of contents

  1. 10.3.1 Projekt „Datenaustausch mit externen Anlagenkomponenten“ p. 234
V 0174 Grundlagen der Automatisierungstechnik mit SIMATIC STEP 7 Solutions · 76 pages 1 experiment

Additional device in this manual View table of contents

  1. 10 Praktische Übungen p. 49