Type 2120
CONTACTOR CONTROL BOARD Type 2120
The CONTACTOR CONTROL BOARD Type 2120 is part of the compact training system from conventional control to the PLC. It covers the basic 24 V contactor experiments, integrated process simulation and the fault simulator, and can be combined with the CONTACTOR BOARD and the AC MULTIFUNCTION MOTOR.
- All introductory contactor control experiments with 24 V
- Integrated process simulation
- Fault simulator for examination-oriented tasks
- Line circuit breakers, load disconnecting switches, main contactors and motor circuit breakers integrated
- Special contactors for direct PLC control
- AC MULTIFUNCTION MOTOR for squirrel-cage, wound-rotor and Dahlander experiments
System structure
Type 2120 is the CONTACTOR CONTROL BOARD of the compact training system from conventional control to the PLC. Together with CONTACTOR BOARD Type 2121.1 and the AC MULTIFUNCTION MOTOR Type 2122 it forms a complete training system for control engineering.
The integrated process simulation and fault simulator make the system suitable for teaching and examinations.
Applications and combinations
The board supports introductory 24 V contactor circuits, different motor applications and direct control from a PLC.
The power components are already integrated, so no special laboratory setup is required.
Technical data and motors
The system data include the 24 V supply, auxiliary contactors, timer relays, safety cover simulation and the separate data of the contactor board and motor board.
The AC MULTIFUNCTION MOTOR supports squirrel-cage, wound-rotor and Dahlander operation modes.
- Operation without special lab equipment
- Supply
- 85 ... 264 V AC, 47 ... 63 Hz; output 24 V DC / 2 A
- Auxiliary contactors
- 4 auxiliary contactors 24 V DC with LEDs, 2 NO and 2 NC each, 250 V AC / 8 A
- Timer relays
- 2 timer relays 24 V DC, 0.5 ... 5 s
- Safety cover simulation
- 2 limit switches and indicator lamp
- Three-phase supply
- 400 V AC, 50 ... 60 Hz
- Main contactors
- 5 main contactors 24 V DC / 2.3 W, 3 NO contacts, 400 V AC / 7 A
- Control board dimensions
- 532 x 297 x 130 mm (W x H x D)
- Control board weight
- 3.6 kg
- Contactor board Type 2121.1 dimensions
- 532 x 297 x 125 mm (W x H x D)
- Contactor board Type 2121.1 weight
- 5.3 kg
- AC multifunction motor dimensions
- 532 x 297 x 270 mm (W x H x D)
- AC multifunction motor weight
- 5.5 kg
- AC multifunction motor delta
- 400 V AC, 0.45 A, 0.1 kW, 1350 rpm, cos phi 0.71
- AC multifunction motor double star
- 400 V AC, 0.5 A, 0.15 kW, 2710 rpm, cos phi 0.8
- 1 Basic 24 V control experiments1
- 1.1 Simple contactor circuits1
- 1.2 Timer contactor circuits1
- 1.3 Emergency stop circuits1
- 1.4 Machine directive safety1
- 1.5 DIN contact labelling1
- 2 Motor applications2
- 2.1 Star-delta circuits2
- 2.2 Star-delta circuits with two directions2
- 2.3 Dahlander motor2
- 2.4 Motor with separate windings2
- 3 PLC and motor applications2
- 3.1 Direct PLC control2
- 3.2 Combination with the AC MULTIFUNCTION MOTOR2
- 4 Technical data3
- 4.1 Supply and auxiliary contactors3
- 4.2 Timer relays and safety cover simulation3
- 4.3 Three-phase supply and main contactors3
- 4.4 Contactor board Type 2121.13
- 5 AC MULTIFUNCTION MOTOR4
- 5.1 Squirrel-cage motor in star-delta operation4
- 5.2 Motor with separate windings4
- 5.3 Dahlander motor4
Taken from the tables of contents of the hps experiment manuals (titles, numbers and pages). Titles are translated into English; page references refer to the German manuals. All manuals and experiments
V 0173 Introduction to open-loop control Manual · 52 pages 20 experiments
Main device of this manual – applies to all experiments View table of contents
- 2.1.1 OR circuit p. 11
- 2.1.2 AND circuit p. 12
- 2.2.1 OR circuit p. 13
- 2.2.2 AND circuit p. 14
- 2.3.1 On-delay relay p. 15
- 2.3.2 Off-delay relay p. 16
- 2.3.3 Flashing circuit p. 18
- 2.4 Contactor interlock p. 19
- 2.5 Button and contactor interlock p. 19
- 2.6.1 Sequence control of a motor with mechanical lock p. 21
- 2.7 Forced-ventilation motor p. 22
- 2.8.1 Advanced gate control p. 27
- 2.9 Machine tool with protective grille p. 30
- 3.1.1 Direct switching on of a motor with start-up override mentioned p. 34
- 3.2.1 Reversing circuit with contactor and button locking mentioned p. 37
- 3.3.1 Automatic star delta connection mentioned p. 40
- 3.3.2 Automatic star-delta reversal circuit mentioned p. 42
- 3.4.1 Pole switching of motors with separate windings mentioned p. 47
- 3.4.2 Motor with direct speed switching p. 49
- 3.4.3 Pole switching with specification of the direction of rotation p. 50
Other sections mentioning this product (5)
- 1.2 Circuit documents p. 5
- 3.1 Directly switching on a motor p. 33
- 3.2 Reversing circuit with contactor locking p. 35
- 3.3 Star-delta circuit p. 38
- 3.4 Pole switching of motors p. 45
No experiment matches the filter.
V 0173 Introduction to open-loop control Solutions · 44 pages 20 experiments
Main device of this manual – applies to all experiments View table of contents
- 2.1.1 OR circuit p. 3
- 2.1.2 AND circuit p. 4
- 2.2.1 OR circuit p. 5
- 2.2.2 AND circuit p. 6
- 2.3.1 On-delay relay p. 7
- 2.3.2 Off-delay relay p. 8
- 2.3.3 Flashing circuit p. 10
- 2.4 Contactor interlock p. 11
- 2.5 Button and contactor interlock p. 11
- 2.6.1 Sequence control of a motor with mechanical lock p. 13
- 2.7 Forced-ventilation motor p. 14
- 2.8.1 Advanced gate control p. 19
- 2.9 Machine tool with protective grille p. 22
- 3.1.1 Direct switching on of a motor with start-up override p. 26
- 3.2.1 Reversing circuit with contactor and button locking p. 29
- 3.3.1 Automatic star delta connection mentioned p. 32
- 3.3.2 Automatic star-delta reversal circuit mentioned p. 34
- 3.4.1 Pole switching of motors with separate windings mentioned p. 39
- 3.4.2 Motor with direct speed switching p. 41
- 3.4.3 Pole switching with specification of the direction of rotation mentioned p. 42
Other sections mentioning this product (3)
- 3.1 Directly switching on a motor p. 25
- 3.3 Star-delta circuit p. 30
- 3.4 Pole switching of motors p. 37
No experiment matches the filter.