SAFETY BOARD Type 2330

Type 2330

SAFETY BOARD Type 2330

The SAFETY BOARD Type 2330 is a compact training system for electrical safety measures according to VDE 0100. All experiments are carried out at extra-low voltage (23 V), require only a single-phase mains outlet and can be performed without any special room installation. With the 2025 device update, insulation resistance, touch voltage and body current are displayed directly on the front panel.

  • Combines all important safety measures according to VDE 0100 in one board
  • Integrated power supply, connection to a single-phase mains outlet (230 V) is sufficient
  • All experiments at extra-low voltage (L1 = 23 V) for safe experimentation
  • Digital insulation monitor with OLED display of response value and present insulation resistance
  • Built-in display of touch voltage and body current at the human symbol
  • Body resistance dry or wet (DRY/WET) selectable with a bridging plug

Application and Safety Concept

With the SAFETY BOARD, hps SystemTechnik provides a training system that is ideally suited for experiments in the field of electrical safety measures.

The unit can be used in any room without special installation because all experiments are carried out at extra-low voltage and the device requires only a single-phase mains supply.

Device Update 2025

With the 2025 device update, the measuring equipment is built directly into the SAFETY BOARD: a digital insulation monitor with OLED display and a display of touch voltage and body current at the human symbol. The experiment topics of the previous SAFETY BOARD are retained.

Touch voltage and body current, the two key measured quantities in electrical safety, can be read simultaneously directly on the unit. As a result, fewer external measuring instruments need to be connected for the experiments. The current display agrees with an external measuring instrument up to approx. 7 mA (measured on the working sample, 07/2025); an external measuring instrument is used for higher currents.

Displays on the Front Panel

The digital insulation monitor shows the set response value (R preset, adjustable from 20 kΩ to 120 kΩ) and the present insulation resistance (R current) on an OLED display. An ERROR LED and RESET and TEST buttons belong to the insulation monitor.

At the human symbol, a second display shows touch voltage and body current (LEAKAGE CURRENT). In measurements on the working sample, the current display agreed with an external measuring instrument up to approx. 7 mA; above that it reads too low.

A bridging plug switches the body resistance from dry (DRY, approx. 2.44 kΩ) to wet (WET, approx. 0.81 kΩ).

Integrated Experiment Environment

The operational status of the most important assemblies is indicated visually by LEDs.

To minimize setup and reset time, all required experiment components are built directly into the SAFETY BOARD, including a residual current device with 3 mA rated residual current, transformer, earth and auxiliary electrodes, and the motor and lamp loads with switchable body faults.

Experiment Manual and Topics

hps SystemTechnik offers the manual "Electrical Safety Engineering" for the SAFETY BOARD with task and solution sections. The corresponding table of contents / experiment manual is linked on the product page as a separate PDF.

A new edition 7.0 of the manual for the current version is in preparation. It adds chapter 15 with experiment 15.2.1 on body current with dry and wet hands.

Setup and Mechanical Design

For experiments, the SAFETY BOARD is placed on the table or suspended in an hps frame for demonstration purposes.

The front panel (532 x 297 mm) is made of blue laminate (HPL) with white circuit symbols corresponding to the integrated functional groups. The labelling is in English.

  • Residual current device with 3 mA rated residual current and test button
  • TT, TN-C-S and IT network configurations selectable by rewiring
  • Integrated experiment components for short setup and reset times
  • Detailed experiment manuals with tasks and solutions available
Mains connection
230 V AC, 50/60 Hz
Simulated mains
L1 = 23 V AC (1/10 of the mains voltage) for safe experimentation; service fuse 3.5 A; miniature circuit breaker 1 A
RCD circuit breaker
Single-phase, with test button; IΔn = 3 mA; tripping time 0.1 s; type AC; 24 V (device label)
Insulation monitor
Digital, OLED display of response value (R preset) and present insulation resistance (R current); response value adjustable 20 kΩ ... 120 kΩ; ERROR LED, RESET and TEST buttons
Human symbol
OLED display of touch voltage and body current; body resistance DRY approx. 2.44 kΩ / WET approx. 0.81 kΩ (bridging plug)
Body current display
Up to approx. 7 mA with a deviation of ≤ 0.1 mA from external measurement, reads too low above that; voltage display 0.2 ... 0.7 V below external measurement (measured on the working sample, 07/2025)
Motor load
Body faults can be simulated via switchable resistances of 2.2 Ω, 10 Ω and 820 Ω
Lamp load
Body faults can be simulated via switchable resistances of 2.2 Ω and 1 kΩ
Transformer
Windings 2 x 11.5 V, 4.5 V and 18.5 V; usable as extra-low-voltage transformer, autotransformer, isolating transformer and summation current transformer
Resistors and adjusters
2 x 50 kΩ, 25 kΩ, 2 x 470 Ω; adjusters 0.5 kΩ ... 2 kΩ and 6 kΩ ... 16 kΩ
Earth electrode / auxiliary electrode
With measuring points for potential funnel measurement at 1 / 2 / 5 / 10 / 20 m; system earth 2 Ω; earthing and location resistances 2.2 Ω, 5.1 Ω, 10 Ω, 25 Ω, 510 Ω, 2.2 kΩ and 10 kΩ
Front panel dimensions
532 x 297 mm (W x H)
Recommended accessories
Experiment manual Electrical Safety Engineering Type V 0119; accessory set Type 2330.1 with connecting leads and 2 mm plugs

Taken from the tables of contents of the hps experiment manuals (titles, numbers and pages). All manuals are in German; titles are translated, the original German title appears on hover. All manuals and experiments

V 0119 Electrical protection Manual · 97 pages 20 experiments
V 0119 Electrical protection Solutions · 24 pages 20 experiments