UNIVERSAL POWER METER Type 1091

Type 1091

UNIVERSAL POWER METER Type 1091

The UNIVERSAL POWER METER Type 1091 is a digital instrument for power, power factor, energy, voltage and current. It is suitable for single-phase and three-phase systems and can also be used as a demonstration meter together with RS 232 visualization software.

  • Universal measuring instrument for power, power factor, energy, voltage and current
  • Suitable for single-phase and three-phase systems
  • Switchable between true RMS and arithmetic measurement
  • 6-digit 7-segment display
  • Additional min and max value measurement
  • Galvanically isolated RS 232 serial interface

Digital meter for a wide range of tasks

The Universal Power Meter is a digital measuring instrument for a very broad field of application. It features a 6-digit 7-segment display and an RS 232 interface.

Power is supplied by an integrated mains unit. In the event of power loss, measured values are retained in a non-volatile memory.

Single-phase and three-phase measurements

The instrument is designed for both single-phase and three-phase networks. For single-phase measurements in a three-phase system with symmetrical load, a fixed phase factor of 3.0 can be activated for power and energy calculations.

The instrument also records min and max values for W, VA, var, V, A and power factor.

Visualization and logging

Visualization software Type 1091.2-EVDE is available as an accessory. It can display up to four measured values simultaneously in analogue and digital form, show one value as a large-format display and store data for later processing, for example in MS Excel.

The integrated data logger enables long-term measurements and Y/t displays with up to three logger channels.

  • Non-volatile measured-value memory during power interruption
  • Can be used as a demonstration instrument with visualization software Type 1091.2
Voltage / current range
0 ... 500 V / 0 ... 20 A
Power factor
0 ... 1
Active power
0 ... 10 kW single-phase, 0 ... 30 kW three-phase
Apparent power
0 ... 10 kVA single-phase, 0 ... 30 kVA three-phase
Reactive power
0 ... 10 kvar single-phase, 0 ... 30 kvar three-phase
Active energy
0 ... 999999 kWh
Apparent energy
0 ... 999999 kVAh
Reactive energy
0 ... 999999 kvarh
Active resistance
0 ... 999999 ohms
Apparent resistance
0 ... 999999 ohms
Reactive resistance
0 ... 999999 ohms
Measuring time
0 ... 999999 h
Accuracy voltage / current
+/-1.0 %, +/-1 digit
Accuracy power
+/-1.0 %, +/-5 digit
Serial interface
Galvanically isolated, bidirectional, 1200 / 2400 / 4800 / 9600 baud, 1 start bit, 8 data bits, 1 stop bit, no parity
Mains connection
110 ... 240 V, 50 ... 60 Hz, approx. 4 VA
Dimensions
133 x 297 x 95 mm (W x H x D)
Weight
approx. 0.9 kg
Recommended accessories
Visualization software Type 1091.2-EVDE; RS 232 cable Type 9102.50; PC with VGA, mouse and free serial interface